LVL performance characteristics : requirements of EN 14279 according to EN 13986:2004+A1:2015

This deals with product use in non structural or structural situations.  Refer also to guidance on essential loadbearing requirements in structural applications as determined by EN 14374  and also relevant standards to determine performance characteristics for end use applications.

Performance

Characteristics

 Structural

 Non-Structural 

EN 13986 Table No.

Internal

Dry

Internal

Humid

Exterior

Floors,

Walls   &

Roofs

Internal

Dry

Internal

Humid

Exterior

Table 1 Table 2 Table 31 Table 7 Table 4 Table 5 Table 61
Bending strength

5.1

5.1

5.1

5.1

5.1

5.1

5.1

Bending stiffness

5.2

5.2

5.2

5.2

Bond quality

5.3

5.3

5.3

5.3

5.3

5.3

5.3

Durability -moisture resistance

5.6.5

5.6.5

5.6.52

5.6.5

5.6.5

Release of formaldehyde

5.7

5.7

5.7

5.7

5.7

5.7

5.7

Reaction to fire

5.8

5.8

5.8

5.8

5.8

5.8

5.8

Water vapour permeability

5.9

5.9

5.9

5.9

5.9

5.9

5.9

Airborne sound insulation

5.10

5.10

5.10

5.10

5.10

5.10

5.10

Sound absorption

5.11

5.11

5.11

5.11

5.11

Thermal conductivity

5.12

5.12

5.12

5.12

5.12

5.12

5.12

Strength & stiffness for structural use 

5.13

5.13

5.13

5.13

Optional/Extra tests for strength & stiffness for structural use3                    See   Clause 5.13

These characteristics may or may not have

been tested by the manufacturer.

Only required for specific end-use applications

      –
Impact resistance for structural use

5.14

Strength & stiffness under point load for structural use

5.154

Racking resistance

5.15.3

5.15.3

5.15.3

5.15.3

Mechanical durability

5.16

5.16

5.16

5.16

Biological durability

5.17

5.17

5.17

5.17

5.17

5.17

5.17

Content of pentachlorophenol (PCP)

5.18

5.18

5.18

5.18

5.18

5.18

5.18

Embedment strength

5.19

5.19

5.19

5.19

Air permeability

5.205

5.205

Notes:

Shaded cells – Essential characteristics which must be determined.
Non-shaded cells – Performance characteristics determined only if required
1   LVL should be used out of direct contact with the ground, soil or water
  For use in humid conditions only
  Tests for strength & stiffness in tension  & compression, panel shear (Modulus of Rigidity), panel shear,
planar shear (Modulus of Rigidity) & planar shear strength
4    Only relevant when intended for structural floor or roof decking on joists
5    Relevant only for use as wind barriers