Rated Sheathing 11.9mm Panel: Bending Strength & Stiffness with Support Spacing ‘Floor-16’
General info: | APA rated OSB Sheathing has a bond durability classification of Exposure 1 as not for exterior use. Panels have one surface with an overlay, texturing or grooving. Creating the tongue reduces the panel width by approximately 12.5 mm (1/2”), so net width may be 1,206mm (47.5 in) |
Bending strength – stress applied parallel: | Factor of safety (F S) bending strength – 445 (lb-in²/ft of panel width) when stress applied parallel to strength axis. The strength axis is always parallel to the face and back orientation of the strands unless otherwise indicated |
Bending strength – stress applied perpendicular: | Factor of safety (F S) bending strength – 165 (lb-in²/ft of panel width) when stress applied perpendicular to strength axis |
Bending stiffness – stress applied parallel: | E I (lb-in²/ft of panel width) – 115,000 when stress applied parallel to strength axis. E I provides a measure of the resistance of the beam to bending. The larger the E I, the smaller the deflection |
Bending stiffness – stress applied perpendicular: | E I – 25,000 when stress applied perpendicular to strength axis |
Span rating/support spacing: | Floor-16 |
Thickness/US Performance Category*: | 11.9mm (min 11.9mm; max 13.5mm); (15/32)* |