Structural 1 Rated Sheathing

15.1mm (Min 14.3002mm Max 15.8496mm)

General Info: Structural I’ indicates it is a performance-rated panel, with superior bending stiffness and strength.
Bending Strength F S (lb-in²/ft of panel width) – stress applied PARALLEL to strength axis: 750
Bending Strength F S (lb-in²/ft of panel width) – stress applied PERPENDICULAR to strength axis N/A
Bending stiffness – stress applied PARALLEL to strength axis: 225000
Bending stiffness – strength applied PERPENDICULAR to strength axis: 89600
Span rating/support spacing: Floor-20
Thicknesses (Minimum and max tolerances): 15.1mm (Min 14.3002mm Max 15.8496mm)
Performance Category: (19/32)

 