Bending Strength for Structural 1 (15.9mm) Panel with Support Spacing ‘Roof-48’
General Info: | Structural 1 indicates a performance-rated panel, with superior bending stiffness and strength |
Bending strength – stress applied parallel: | Factor of safety (F S) – 1,000 (lb-in²/ft of panel width) when stress applied parallel to strength axis. The strength axis is always parallel to the face and back orientation of the strands unless otherwise indicated |
Bending strength – stress applied perpendicular: | Factor of safety (F S) – 607.5 (lb-in²/ft of panel width) when stress applied perpendicular to strength axis |
Bending stiffness – stress applied parallel to strength axis: | N/A |
Bending stiffness – stress applied perpendicular to strength axis: | N/A |
Span rating/support spacing: | Roof-48 |
Thickness/US Performance Category*: | 18.2mm (min 17.47mm; max 19.05mm); (23/32)* |